- -30…+75°C
- 16 measuring ranges per device
- output 0-10 V, 4-20 mA
- aluminium globe
- measuring of the thermal radiation
- hinge lock technology
The TPM1/E room pendulum transducer registers the heat radiation in, for example, high rooms and converts this measured value into a linear output signal 0-10 V respectively 4-20 mA. As an option the temperature transducer has two potential-free changeover contacts and a backlit display. The display content can be rotated in 90° steps using a menu and the measured value, the switching threshold set, the state of the respective relay, the MIN/MAX measured values for the selected intervals(1 h / 6 h / 12 h / 24 h) etc. can be read out.On the display version the user can, via the menu, specify an individual temperature range.The temperature transducer is simply hung in the room as a pendulum, whereby an accurate measurement result for the perceived room temperature is ensured in high rooms.
Measurement range temp.: | -30…+75°C |
Measurement range configuration: | 1 freely programmable measuring range via the menu input in the display (span min. 25K) |
Scales: | -50…0°C, -50…+50°C, -50…+150°C, -30…+20°C, -30…+70°C, -20…+50°C, -20…+80°C, -20…+120°C, -20…+150°C, -10…+15°C, 0…+50°C, 0…+100°C, 0…+150°C, 0…+200°C, 0…+250°C, +10…+35°C |
Accuracy: | ±0,2 K + max. ±1,5% Span |
Supply voltage analog 0-10 V: | 24 V AC/DC (±5%) |
Supply voltage analog 4-20 mA: | 15…36 V DC, depends on liability (Ubmin = 15 V + Rload*0,02A) |
Current consumption at 0-10 V: | typ. 10 mA, 30 mA peak current consumption for 50 ms at switching moment at option relay |
Current consumption at 4-20 mA: | max. 20 mA / output, 40 mA peak current consumption for 50 ms at switching moment at option relay |
Analogue output 0-10 V: | 3-wire connection, min. load resistance 100 kOhm |
Analogue output 4-20 mA: | 2-wire connection (transmitter), max. RLoad(Ohm) = (+Ub – 15 V) / 0,02 A |
Alarm output: | 2 x potential-free change-over contact, 48 V, 1 A |
Switching Hysteresis Relay: | Temperature: 2K (without display), 0,5…5K adjustable (with display) |
Electrical connection: | screw terminals max. 1,5 mm² |
Display: | optional LCD display with backlight on/off/auto |
Cable: | 2 m PVC cable (max. +105°C) |
Material: | Globe: aluminium (black) |
Cable gland: | PG11 high-strength cable gland with strain relief |
Housing: | Polycarbonate PC UL 94 V0 with hinge locks, color signal white similar to RAL 9003 |
Dimensions: | Housing: L 89 x W 80 x H 47 mm, Globe: Ø 70 mm |
Protection type: | IP65 (housing), IP54 (probe) |
Protection class: | III |
Working range r.H.: | 0…98% r.H. in contaminant-free, non-condensing air |
Working temperature: | Probe: -30…+75°C, Electronic: -20…+70°C |
Storage temperature: | -20…+70°C |
Installation: | screw fastening |
Approvals: | CE, EAC, RoHS |