  • -30…+75°C
  • 16 measuring ranges per device
  • output 0-10 V, 4-20 mA
  • aluminium globe
  • measuring of the thermal radiation
  • hinge lock technology

  • The TPM1/E room pendulum transducer registers the heat radiation in, for example, high rooms and converts this measured value into a linear output signal 0-10 V respectively 4-20 mA. As an option the temperature transducer has two potential-free changeover contacts and a backlit display. The display content can be rotated in 90° steps using a menu and the measured value, the switching threshold set, the state of the respective relay, the MIN/MAX measured values for the selected intervals(1 h / 6 h / 12 h / 24 h) etc. can be read out.On the display version the user can, via the menu, specify an individual temperature range.The temperature transducer is simply hung in the room as a pendulum, whereby an accurate measurement result for the perceived room temperature is ensured in high rooms.

    Measurement range temp.: -30…+75°C
    Measurement range configuration: 1 freely programmable measuring range via the menu input in the display (span min. 25K)
    Scales: -50…0°C, -50…+50°C, -50…+150°C, -30…+20°C, -30…+70°C, -20…+50°C, -20…+80°C, -20…+120°C, -20…+150°C, -10…+15°C, 0…+50°C, 0…+100°C, 0…+150°C, 0…+200°C, 0…+250°C, +10…+35°C
    Accuracy: ±0,2 K + max. ±1,5% Span
    Supply voltage analog 0-10 V: 24 V AC/DC (±5%)
    Supply voltage analog 4-20 mA: 15…36 V DC, depends on liability (Ubmin = 15 V + Rload*0,02A)
    Current consumption at 0-10 V: typ. 10 mA, 30 mA peak current consumption for 50 ms at switching moment at option relay
    Current consumption at 4-20 mA: max. 20 mA / output, 40 mA peak current consumption for 50 ms at switching moment at option relay
    Analogue output 0-10 V: 3-wire connection, min. load resistance 100 kOhm
    Analogue output 4-20 mA: 2-wire connection (transmitter), max. RLoad(Ohm) = (+Ub – 15 V) / 0,02 A
    Alarm output: 2 x potential-free change-over contact, 48 V, 1 A
    Switching Hysteresis Relay: Temperature: 2K (without display), 0,5…5K adjustable (with display)
    Electrical connection: screw terminals max. 1,5 mm²
    Display: optional LCD display with backlight on/off/auto
    Cable: 2 m PVC cable (max. +105°C)
    Material: Globe: aluminium (black)
    Cable gland: PG11 high-strength cable gland with strain relief
    Housing: Polycarbonate PC UL 94 V0 with hinge locks, color signal white similar to RAL 9003
    Dimensions: Housing: L 89 x W 80 x H 47 mm, Globe: Ø 70 mm
    Protection type: IP65 (housing), IP54 (probe)
    Protection class: III
    Working range r.H.: 0…98% r.H. in contaminant-free, non-condensing air
    Working temperature: Probe: -30…+75°C, Electronic: -20…+70°C
    Storage temperature: -20…+70°C
    Installation: screw fastening
    Approvals: CE, EAC, RoHS