- -30…+80°C
- 16 measuring ranges per device
- output 0-10 V, 4-20 mA
- DIP-switch-technology
- optional with LCD-Display
- tightened rod by copper core
- protection type IP65
- incl. mounting flange
- hinge lock technology
The MM/E average temperature transducer registers the average temperature value in gaseous media and converts this measured value into a linear output signal 0-10 V respectively 4-20 mA.As an option the temperature transducer has two potential-free changeover contacts and a backlit display. The display content can be rotated in 90° steps using a menu and the measured value, the switching threshold set, the state of the respective relay, the MIN/MAX measured values for the selected intervals(1 h / 6 h / 12 h / 24 h) etc. can be read out.On the display version the user can, via the menu, specify an individual temperature range.Using the installation flange, included in the scope of delivery, the temperature transducer is fastened, for example, directly to the duct, and the copper rod can be mounted meander formed in air ventilation ducts using the mounting clamps. This determines the average temperature for the total cross-section or over a specified length. For improved quality the rod sensor is fitted with a copper rod.
Measurement range temp.: | -30…+80°C |
Measurement range configuration: | 1 freely programmable measuring range via the menu input in the display (span min. 25K) |
Scales: | -50…0°C, -50…+50°C, -50…+150°C, -30…+20°C, -30…+70°C, -20…+50°C, -20…+80°C, -20…+120°C, -20…+150°C, -10…+15°C, 0…+50°C, 0…+100°C, 0…+150°C, 0…+200°C, 0…+250°C, +10…+35°C |
Accuracy: | ±0,2 K + max. ±1,5% Span |
Supply voltage analog 0-10 V: | 24 V AC/DC (±5%) |
Supply voltage analog 4-20 mA: | 15…36 V DC, depends on liability (Ubmin = 15 V + Rload*0,02A) |
Current consumption at 0-10 V: | typ. 10 mA, 30 mA peak current consumption for 50 ms at switching moment at option relay |
Current consumption at 4-20 mA: | max. 20 mA / output, 40 mA peak current consumption for 50 ms at switching moment at option relay |
Analogue output 0-10 V: | 3-wire connection, min. load resistance 100 kOhm |
Analogue output 4-20 mA: | 2-wire connection (transmitter), max. RLoad(Ohm) = (+Ub – 15 V) / 0,02 A |
Alarm output: | 2 x potential-free change-over contact, 48 V, 1 A |
Switching Hysteresis Relay: | Temperature: 2K (without display), 0,5…5K adjustable (with display) |
Electrical connection: | screw terminals max. 1,5 mm² |
Display: | optional LCD display with backlight on/off/auto |
Material: | Rod: copper (oxidation protective coating, black) |
Cable gland: | PG11 high-strength cable gland with strain relief |
Housing: | Polycarbonate PC UL 94 V0 with hinge locks, color signal white similar to RAL 9003 |
Dimensions: | Housing: L 89 x W 80 x H 47 mm, Rod length: 0,4 m, 3 m and 6 m (Ø 6 mm) |
Protection type: | IP65 |
Protection class: | III |
Working range r.H.: | 0…98% r.H. in contaminant-free, non-condensing air |
Working temperature: | Probe: -30…+80°C, Electronic: -20…+70°C |
Storage temperature: | -20…+70°C |
Installation: | housing by mounting flange (in scope of delivery), rod by mounting clamps (in scope of delivery), max. bending radius 35 mm (beware of loading by vibration) |
Approvals: | CE, EAC, RoHS |