Produktdetails

Pressure Transducer for differential pressure/ volume flow/ atmospheric and barometric air pressure, with display, with changeover contact, Modbus RTU

Ursprünglicher Preis war: 207,19 €Aktueller Preis ist: 51,80 €.

SKU SK0120434-U Category Tag

24-Stunden-Versandgarantie

Bis zu 30 Tage für Rücksendungen

  • +/-100 Pa, +/-500 Pa, +/-5000 Pa, 0-200.000 m³/h
  • Air pressure 500…1150 mbar
  • Modbus RTU, Relay
  • output attenuation
  • input altitude above sea level
  • hinge lock technology

  • The pressure transducer FS1200 registers the over-pressure, under-pressure, the pressure difference at the two pressure inlets, also the atmospheric and barometric air pressure, and converts the measured value into a digital output signal.In the register, the K-factor and calculation formula for calculating volumetric flow, the unit, the height above the sea level, the output attenuation hysteresis, offset value etc can be specified. A zero point adjustment can be performed using a command.As special equipment a potential-free alternating contact and/or a backlit display are available The contents of the display can be rotated in steps of 90° by using a command.As special functions a series of defined measured values from other bus-participants (also cross-manufacturers) can be shown in the display. To display measured values from other bus-participants these are entered into the corresponding register by the bus-Master. The optional alternating contact can be configurated for measured values from other bus-participants.The configuration of address, transmission mode/speed, terminating resistor and master/slave function of the bus-devices can easily be done using the innovative DIP switch technology. Thus devices can quickly and easily integrated into the system and later parameterised via the master.The bus-devices can even be reset to the works settings during operation of the master. Thus the basic functionality of the device is recreated in a matter of seconds. This can be necessary in the event of incorrect parameterisations of, e.g. offset, switching threshold, display modes etc..By means of the FS master/slave topology autarkic nodes without additional SPS master can be installed within the device series. Hereby a bus-device assumes the master function in the node. This requests the measured values from other bus-participants, automatically enters these into the corresponding register and shows them in the internal display. Furthermore the master can evaluate and operate additional actuators in the device series (analogue in- and outputs, relay station).

    Measurement range atm. air pressure: 500-1150 mbar
    Measurement range bar. air pressure: 500-1150 mbar
    Measurement range differential pressure: P21: -100…+100 Pa, P22: -500…+500 Pa, P23: -5000…+5000 Pa
    Measurement range volume flow (calculated): V1: 0-65.000 m³/h, V2: 0-200.000 m³/h, V3: 0-30.000 m³/h
    Accuracy: pressure difference: ±3,0% FS (at 20°C); air pressure ±5 mbar (at 20°C)
    Temperature dependency: pressure difference: ±2,5% FS / 10 K; air pressure : 1 mbar / 10 K
    Linearity inaccuracy: pressure difference / air: ±1,0% final value
    Pressure resistance: 5-times of measurement range
    Supply voltage: 24 V DC (±5%)
    Current consumption: max. 30 mA + 30 mA (option display) + 20 mA (option relay)
    Alarm output: 1 x potential-free change-over contact, 48 V, 1 A
    Digital output: Modbus RTU
    Switching Hysteresis Relay: can be entered in the register
    Offset: air pressure: can be entered in the register
    Electrical connection: push-in terminal, no tools required, time-saving
    Display: optional LCD display with backlight on/off/auto
    Output attentuation: can be entered in the register
    Cable gland: PG11 high-strength cable gland with strain relief
    Housing: Polycarbonate PC UL 94 V0 with hinge locks, color signal white similar to RAL 9003
    Dimensions: Housing: L 89 x W 80 x H 47 mm
    Protection type: IP65, IP30 (with air pressure sensor)
    Protection class: III
    Working range r.H.: 0…98% r.H. in contaminant-free, non-condensing air
    Working temperature: 0…+50°C
    Manual zero-point adjustment: A manual zero adjustment can be performed by command.
    Storage temperature: 0…+50°C
    Installation: Housing: screw fastening, Pressure connection: 2 plastic duct connecting nipple with fastening screws and 2 m PVC tube Ø 6 mm (in scope of delivery)
    Approvals: CE, EAC, RoHS