Produktdetails

Pressure Transducer for differential pressure/ flow rate, with display, with changeover contact, 0-10 V or 4-20 mA

Ursprünglicher Preis war: 228,28 €Aktueller Preis ist: 57,07 €.

SKU SK0120438-U Category Tag

24-Stunden-Versandgarantie

Bis zu 30 Tage für Rücksendungen

  • -5000…+5000 Pa, 0-200.000 m³/h
  • 8 measurement ranges per version
  • 0-10 V, 4-20 mA,relay
  • output attenuation 0 sec. / 1 sec. / 5 sec. / 10 sec. by DIP-switch selectable
  • hinge lock technology

  • The pressure transmitter detects the overpressure, underpressure or differential pressure (P) between the two pressure inputs and converts the measured value into a linear output signal 0-10 V or 4-20 mA. 8 different scalings and the output damping of the pressure transmitter (0 sec / 1 sec / 5 sec / 10 sec) can be set on the device.Alternatively, the measuring device can be operated as a volume flow measuring device. It calculates the volume flow (Q) using the system-specific K factor (k) and outputs the calculated value as a linear output signal 0-10 V or 4-20 mA. The K-factor, the desired scaling for the volume flow output signal 0-10 V or 4-20 mA, the density of the medium and the desired volume unit (l or m³ per s / min / h) can be conveniently set via the display menu.The content of the backlit display can be rotated in 90 ° steps via the menu and the actual value, the set switching threshold, the relay status, the MIN / MAX measured values of the selected interval (1 h / 6 h / 12 h / 24 h) etc. can be read. For manual calibration of the zero point on site, the pressure transmitter carries out a zero point adjustment at the push of a button. If necessary, the pressure transmitter can be fine-calibrated on site using a SPAN controller.

    Pressure type: positive, negative or differential pressure
    Medium: air, non-aggressive, non-flammable, non-condensing gases
    Measurement range pressure: V1: 0…+/-500 Pa, V2: 0…+/-5000 Pa, V3: 0…+/-100 Pa
    Measurement range volume flow (calculated): V1: 0-65.000 m³/h, V2: 0-200.000 m³/h, V3: 0-30.000 m³/h
    Scales: V1: 0…+/-100, 0…+/-200 Pa, 0…+/-300 Pa, 0…+/-500 Pa; V2: 0…+/-1000, 0…+/-2000 Pa, 0…+/-3000 Pa, 0…+/-5000 Pa; V3: 0…+/-25, 0…+/-50 Pa, 0…+/-75 Pa, 0…+/-100 Pa
    Accuracy: ±3,0% FS (at 20°C)
    Temperature dependency: ±2,5% FS / 10 K
    Linearity inaccuracy: ±1,0% final value
    Long term stability: ±1% FS/year
    Zero-point adjustment: max. +2% final value
    Pressure resistance: 5-times of measurement range
    Sensor protection: mounted inside housing
    Supply voltage analog 0-10 V: 24 V AC/DC (±5%)
    Supply voltage analog 4-20 mA: 15…36 V DC (Ubmin = 15 V + RLoad*0,02A)
    Current consumption at 0-10 V: typ. 15 mA, 30 mA peak current consumption for 50 ms at switching moment at option relay
    Current consumption at 4-20 mA: max. 20 mA / output, 40 mA peak current consumption for 50 ms at switching moment at option relay
    Analogue output 0-10 V: 3-wire connection, min. load resistance 100 kOhm
    Analogue output 4-20 mA: 2-wire connection (transmitter), max. RLoad(Ohm) = (+Ub – 15 V) / 0,02 A
    Alarm output: 1 x potential-free change-over contact, 48 V, 1 A
    Switching Hysteresis Relay: 2% of the selected scaling (without display), 0,5…5% of the selected scaling adjustable (with display)
    Offset: ±5% from the selected scale by 270° potentiometer
    Electrical connection: screw terminals max. 1,5 mm²
    Display: optional LCD display with backlight on/off/auto
    Output attentuation: 0 s / 1 s / 5 s / 10 s selectable by DIP switch
    Running-in time: < 30 min at initial operation because of tempering
    Reaction rate: < 1 s, at 5% alteration relating to final value
    Cable gland: PG11 high-strength cable gland with strain relief
    Housing: Polycarbonate PC UL 94 V0 with hinge locks, color signal white similar to RAL 9003
    Dimensions: Housing: L 89 x W 80 x H 47 mm
    Protection type: IP65, IP20 if pressure connection port is open
    Protection class: III
    Working range r.H.: 0…98% r.H. in contaminant-free, non-condensing air
    Working temperature: 0…+50°C
    Manual zero-point adjustment: The zero point adjustment is started by pressing the button on the circuit board (push 10 s until LED stops flashing or by the display version the countdown 10-0 is completed). Before, a continuous operation of at least 1 hour must be sure, the offset must be in the middle position and the pressure inputs P+ and P- must be an obvious offense to the environment. The successful calibration will be signalized by 5 sec durable lightning of the LED.
    Storage temperature: 0…+50°C
    Installation: Housing: screw fastening, Pressure connection: 2 plastic duct connecting nipple with fastening screws and 2 m PVC tube Ø 6 mm (in scope of delivery)
    Approvals: CE, EAC, RoHS