- 0-200/500/1000 ppm
- 0-10 V, 4-20 mA, changer
- optional LCD-Display
- hinge lock technology
The air quality sensor CO-A/A registers the CO concentration in the air in the environment in the range of 0-1000 ppm via an electro-chemical sensor and converts this measured value into a linear output signal 0-10 V respectively. 4-20 mA.As an option the air quality sensor has a potential-free changeover contact and a backlit display. The display content can be rotated in 90° steps using a menu and the measured value, the switching threshold set, the state of the relay, the MIN/MAX measured values for the selected intervals (1 h / 6 h / 12 h / 24 h) etc. can be read out.3 different measuring ranges can be selected 0-200 ppm, 0-500 ppm, 0-1000 ppm which can be switched, according to requirements, by the innovative DIP switching technology.
Measurement range CO: | 0-1000 ppm |
Scales: | 0-200/500/1000 ppm |
Accuracy: | ±5 ppm + max. ±5% f. mv (at 20°C, 50% r.H.) |
Temperature dependency: | CO: ±2 ppm / K |
Long term stability: | ±1% FS/year |
Sensor: | Electrochemical sensor |
Response time (t90): | < 5 min |
Sensor protection: | sinter filter |
Supply voltage: | 24 V AC/DC (±5%) |
Current consumption: | max. 100 mA |
Analogue output 0-10 V: | 3-wire connection |
Analogue output 4-20 mA: | 3-wire connection |
Alarm output: | 1 x potential-free change-over contact, 48 V, 1 A |
Switching Hysteresis Relay: | 2% FS (without Display), 0,5…5% FS adjustable (with Display) |
Electrical connection: | screw terminals max. 1,5 mm² |
Display: | optional LCD display with backlight on/off/auto |
Running-in time: | 1 min |
Initial operation: | After switch-on of the device it runs a self-test and the zero-point calibration. This process takes, depending on ambient conditions, about 1 minutes. Within this time, the linear output signal deviates from the actual measured value. |
Cable gland: | PG11 high-strength cable gland with strain relief |
Housing: | Polycarbonate PC UL 94 V0 with hinge locks, color signal white similar to RAL 9003 |
Dimensions: | Housing: L 89 x W 80 x H 47 mm |
Protection type: | Housing/electronic: IP65, Sensor: IP30 |
Protection class: | III |
Working range r.H.: | 0…98% r.H. in contaminant-free, non-condensing air |
Working temperature: | 0…+50°C |
Storage temperature: | -20…+50°C |
Installation: | screw fastening |
Approvals: | CE, EAC, RoHS |